Kaba E-Plex 5900 User Manual page 21

Card connect lock
Hide thumbs Also See for E-Plex 5900:
Table of Contents

Advertisement

5
1
2
6
1
2
7
1
16.2 In Access mode
Step
Sub
1
1.1
1.2
1.3
2
1
Enter communication mode by typing:
900#
o
Click 'Send' on the maintenance unit 'Set
Time' dialog
Configure the lock using the admin card
Enter the lock configuration command
(where valid users will be transferred to
lock via the Admin card):
100#
o
Present the Admin card to the lock
Exit keypad programming mode
Press '#' key
Description/Operation
Enter lock keypad programming.
Start keypad programming mode
Press '#' key
o
If the lock is configured for PIN and card:
Type in PIN
o
Press '#' key
o
Present a valid user card having 'update
using admin card' privilege to the lock
Configure the lock using the admin card
Enter the lock configuration command
(where valid users will be transferred to
lock via the Admin card):
100#
o
prevent user credential validation and so the
lock will deny access to keypad
programming modes (like date/time setting).
The green led blinks with high pitch sound to
confirm the command and then red and
green leds blink in alternate sequence to
indicate communication mode is activated.
The communication with the maintenance
unit must be established within 15 seconds
Once the time is set, an 'ok' dialog box will
be displayed and the lock will respond with a
high pitch sound.
The green led will blink to indicate that it is
waiting for the Admin card.
Once the lock reads and processes the
Admin card, the green led will turn on with a
high pitch sound indicating success.
[After exiting the keypad programming mode
as shown on the next step, the lock is now in
(user credential) access mode. A valid ISO
14443A DESFire user card will now operate
the lock].
Either exit pressing the '#' key or leave the
lock idle for five seconds. In the latter case,
the red led turns on with a low pitch sound to
indicate a timeout.
Green led blinks with high pitch sound
Notes
If programming mode is entered, the green
led turns on along with a high pitch sound.
If the user does not have the 'update using
admin card' privilege, access will be denied
(red led low pitch sound). The green led will
blink to indicate that it is waiting for the
21