Exiting Keypad Programming Mode; Commands - Kaba E-Plex 5900 User Manual

Card connect lock
Hide thumbs Also See for E-Plex 5900:
Table of Contents

Advertisement

commands are then entered by pressing 3 numbers pertaining to the command code followed by a #. Then,
depending on the command, one or more parameters are entered, separated by # keys. The # key acts as a
confirmation (like an "Enter" key on a PC keyboard). Finally, press the # key again to exit the keypad programming
mode:
# Command# parameters# parameters# ... #
Example of a complete command sequence: To set date (001 command code) & time (002 command code),
assuming 87654321 is the construction PIN, and the date and time you are setting is June, 19
# 87654321# 001# 061907# 061907# 002# 1330# 1330# #
Maximum 5 seconds are allowed between key presses and a maximum of 15 seconds between command
sections. Note that the * key can be used to clear the current parameter or command. The following table lists the
different methods of entering in keypad programming mode:
Mode
Factory
Construction
Access

13.2 Exiting keypad programming mode

To exit keypad programming after a command was entered, do one of the following:
Leave the lock idle for 5 seconds. Red led will turn on with low pitch tone, or
Press the # key. Green led will turn on, followed with 2 high pitch beeps.

13.3 Commands

The following table list the lock keypad commands recognized by the lock. Remember that privileges are required
to access commands once the lock is configured. If the cardholder does not have the required privilege to access
a command, the red led is turned on. Once a command is entered successfully, the green led will turn on with high
pitch sound (same for its parameters). If the command is executed successfully, the green led is turned on with 2
high pitch beeps.
Name
Set construction pin
Procedure
Enter the factory default pin by pressing the keys in the following sequence:
#12345678#
Press the keys in the following sequence where the PIN must be 8 digits in length:
#PIN#
Where PIN is the construction pin which must be different from the factory pin.
If the lock was configured for pin and card, enter the following sequence:
1. #PIN#
2. Present card
Where PIN is the cardholder pin (anywhere from xx to 20 digits?)
If the lock was configured for card only, enter the following sequence:
1. #Present card
Command keys
Parameters
000#
XXXXXXXX#XXXXXXXX#
12
12/37
th
2007, 1:30PM):

Advertisement

Table of Contents
loading

Table of Contents