Hex Transparent Control

This option allows you to enable (the default) or disable additional features that
are not available in standard IBM emulations. To access these features, send lead-in
character text commands in the data stream. You can also use ASCII codes X'80'
through X'9F' as control codes if configured to do so.
Lead-In Characters
The Lead-In Character commands must have a start and end code. Set 1 is the
factory default. Three sets (each containing a start and end code) are available:
v Set 1:
v Set 2:
v Set 3:
v User Defined
User Defined Codes
v Start Code 2: X'5F' (the default)
v Start Code 1: X'5F'
v Stop code: X'5B'
The codes can be set to X'40' - X'FF' range
Alternate Set 80 - 9F
This selection determines if ASCII codes X'80' through X'9F' will be used as control
codes or printed as standard printable characters.
v Printable (the default). Prints the alternate set as standard characters
v Control Code. Selects the alternate set to be used as printer control codes.
62
InfoPrint 6500-V User's Manual
start code = <% (default)
end code = >
start code = ¬¬
end code = $
start code = _%
end code = _