5.1. Opening and Closing the KBox E-200 Series
Before opening the KBox E-200 Series, the system must be switched off and
disconnected from the main power supply. Also, disconnect all peripheral devices from
the KBox E-200 Series. Before you begin, ensure that you have a clean, flat and ESD-
safe surface to work on.
For opening and closing the KBox E-200 Series, please perform the following steps:
1.
Close all applications. Shut down the system properly and disconnect the connection to the main power source.
Disconnect all peripherals.
2.
The KBox E-200 Series should lay on a flat, clean surface with the access cover facing upwards.
3.
Loosen and remove the Phillips screws (two located on front I/O panel, five on the bottom and additional one on
the bottom (marked in blue in Figure 5) for fixing hard disk if installed), that secure the access cover to the
chassis. Retain the screws for later use.
Figure 5: Descrewing the access cover of the KBox E-200 Series
4.
Slightly slide the access cover toward the front of the system and them lift it up.
5.
Now you have access to the internal DDR3L SO-DIMM, SATA, mSATA, mPCIe and SIM sockets respectively in order
to remove or install hardware components.
www.kontron.com
KBox E-200 Series - User Guide, Rev. 1.0