Performance - GE MDS SD4A Technical Manual

Mds sd4 series
Table of Contents

Advertisement

Radio Performance
MDS 05-4846A01, Rev. F
Never assert Alarm Signal
Assert Signal on Major Alarm
Assert Signal on Major or Minor Alarm
Assert Signal on Any Alarm or Status
Set Alarm Bits
—This button is used to set the selections made in
the check box list below it. First, you must select which specific
alarms will result in a signal being produced by the alarm output
line. To set an alarm/message for reporting by the output line,
simply click the check box next to an item of interest. To clear a
check box, simply click it again. When you are finished with the
selections, click the
Undo
—This button may be used to return the screen to its original
selections. It clears any selections made prior to clicking the
Alarm Bits
button.

Performance

This screen contains several measurement parameters that can be used
to check the operating conditions of the radio.
Measured RF Power
output power (in dBm).
Signal to Noise
—Read-only indication of the signal-to-noise ratio
of received signal.
RSSI
—Read-only indication of the received signal strength (in
dBm).
DC Voltage
—Read-only indication of the DC supply voltage
applied to the transceiver.
Temperature
—Read-only indication of the chassis temperature
(degrees C).
SD Series Technical Manual
Set Alarm Bits
button.
—Read-only indication of the measured RF
Set
71

Hide quick links: