Ping Test
74
NOTE: No other data traffic should be active when performing a Link-
test.
Destination Unit Address
being tested.
Linktest Count
—Enter the number of times for the message to be
sent across the radio link.
Response Timeouts (msec)
will result in a timeout if no response is received in within that
period.
Start Test
—Set this box to
the test.
When you are done with the settings above, press
apply the changes.
Refresh
—Clicking this button updates the displayed statistics on
demand.
Auto
—Initiates automatic updating of statistics. A time (in sec-
onds) may be entered in the box provided, to specify how often
the display is updated.
A connectivity test to a specific destination address may be performed
using the radio's Ping Test screen.
Destination Address
ping tested.
Count
—Enter the number of pings to send across the radio link.
Bytes
—Enter the number of bytes in each ping.
Interval
—Use this box to specify how long (in seconds) between
ping transmissions after a response is received.
Timeout
—Use this box to specify how long (in seconds) to wait
for a ping response before a timeout occurs.
SD Series Technical Manual
—Enter the Unit Address of the other radio
—Enter the time (in milliseconds) that
ON
to start the Link Test, or
—Enter the IP Address of the other radio being
OFF
to stop
Commit Configuration
to
MDS 05-4846A01, Rev. F