Placing Pump Back Into Service

1.
If shop test stand is available, use the following proce-
dure for testing rebuilt pumps:
a. Mount pump on test stand. Make sure proper level
of clean oil is available in reservoir. Check suction
line for leaks and obstructions.
b. Start pump and run for three minutes at zero pres-
sure.
c. Intermittently load pump to 500 psi (34 bar) for
three minutes.
d. Intermittently load pump to 1000 psi (69 bar) for
three minutes.
e. Intermittently load pump to 2000 psi (138 bar) for
three minutes.
f. Remove pump from test stand and check for free-
ness of drive shaft. Check pump for signs of external
leakage.
2. If shop test stand is not available, use the following proce-
dure for testing rebuilt pumps:
a. For engine driven pumps, mount pump on equip-
ment and run pump at 1/2 engine speed at zero
pressure for three minutes.
b. Operate control valve and build pressure intermit-
tently for three minutes.
c. Increase engine speed to full throttle and build
pressure intermittently for three minutes.
d. Stop engine and check pump for external leaks.
3121298

5.7 VARIABLE PUMP

Ports and Pressure Gauges

Proper servicing of pumps and motors requires pressure mea-
sured and monitored at various hydraulic circuit points. The
Series 42 pump has several locations at which to take these
measurements. The following outlines show gauge port loca-
tions, and gauge and fitting size for each port.
Table 5-2. Recommended Gauge Size
Gauge
Pressure
Port
Measured
Name
M1 & M2
System
Pressure
Ports A & B
M3
Charge
Servo
M4 & M5
Case
L1 & L2
Charge Pump
S
Inlet Vacuum

NFPE Control

The 3-position FNR control, and electric and hydraulic non-
feedback proportional (NFPE and NFPH) controls are non-
feedback type controls. FNR and NFPE controls consist of
pump housing mounted modules. Hydraulic input for NFPH is
received through ports on top of pump [9/16–18 SAE O-ring
fitting].
Non-feedback controls are factory set. Control modules can be
removed to clean ports and change O-rings.
FNR and NFPE orifice plugs are located inside the servo piston
covers. NFPH orifice plugs are located in the NFPH ports. Ori-
fice plugs may be cleaned or replaced.
– JLG Lift –
SECTION 5 - HYDRAULICS
Recommended Gauge
Size
Fitting
psi
bar
10000
689
9/16-18
1000
69
3/4-16
1000
69
9/16-18
500
34
1-1/16-12
30 in. Hg Vac.
1
1-1/16-12
ORF
ORF
ORF
ORF
ORF
5-45

Advertisement

Table of Contents
loading

This manual is also suitable for:

600s

Table of Contents