SECTION 3 - CHASSIS & TURNTABLE
Table 3-9. Coupling Port Information Table - 2WS
Port
Port
Description
Outlet
No.
Size
1
1
-8
Brake
2
2
-6
2 Speed
3
1
-6
Steer
4
1
-6
Steer
5
2
-6, -16
Drive Reverse
6
1
-16
Drive Forward
7
3
-8, -6
Case Drain
Table 3-10. Coupling Port Information Table - 4WS
Port
Port
Description
Outlet
No.
Size
1
1
-8
Brake
2
2
-6
2 Speed
3
1
-6
Steer
4
1
-6
Steer
5
2
-6, -16
Drive Reverse
6
1
-16
Drive Forward
7
3
-8, -6
Case Drain
8
1
-6
Steer
9
1
-6
Steer
3-52
Operating
Proof
Pressure
Pressure
PSI (Bar)
PSI (Bar)
450 (31)
675 (47)
4500 (310)
6750 (465)
2500 (172)
3750 (259)
2500 (172)
3750 (259)
4500 (310)
6750 (465)
4500 (310)
6750 (465)
250 (17)
375 (26)
Operating
Proof
Pressure
Pressure
PSI (Bar)
PSI (Bar)
450 (31)
675 (47)
4500 (310)
6750 (465)
2500 (172)
3750 (259)
2500 (172)
3750 (259)
4500 (310)
6750 (465)
4500 (310)
6750 (465)
250 (17)
375 (26)
2500 (172)
3750 (259)
2500 (172)
3750 (259)
– JLG Lift –
3.10 GENERATOR
Every 250 hours
Check drive belt tension every 250 hours of operation,.
1/2 in.
(13 mm)
Figure 3-69. Generator Belt Tension
Every 500 hours
Service generator brushes and slip rings every 500 hours of
operation. Hostile environments may require more frequent
service.
Figure 3-70. Generator Brushes and Slip Rings
Blow out inside of generator every 500 hours of service. If
operating in a hostile environment, clean monthly.
Figure 3-71. Generator Cleaning
3121298