SECTION 6 - JLG CONTROL SYSTEM
From
DIAGNOSTICS:
DIAGNOSTICS:
ENGINE
BOOM FUNCTIONS
START SEQUENCE:
NOT ACTIVE
BATTERY VOLTAGE:
XX.XV
COOLANT
TEMPERATURE:XXXF
ELECTRIC FAN
OUTPUT: OFF
ELECTRIC FUEL
PUMP OUTPUT: OFF
ENGINE OIL
PRESSURE:XXX PSI
FUEL SELECTION
SWITCH: GAS
FUEL SELECTION
STATUS: GAS
AMBIENT
TEMPERATURE:XXXF
FUEL LEVEL
SENSOR: OK
STARTER
CRANK TIME: XX S
ENGINE SPEED
ACTUAL: XXXX RPM
ENGINE SPEED
TARGET: XXXX RPM
6-10
DIAGNOSTICS:
SYSTEM
GROUND MODULE:
BATTERY: XX.XV
PLATFORM MODULE:
BATTERY: XX.XV
AMBIENT
TEMPERATURE:XXXF
PLATFORM SELECT
KEYSWITCH: OPEN
GROUND SELECT
KEYSWITCH: OPEN
STATION CONTROL:
GROUND
FOOTSWITCH INPUT
GROUND: OPEN
FOOTSWITCH INPUT
PLATFORM: OPEN
TRANSPORT
SWITCHES: OPEN
TRANSPORT MODE:
OUT OF TRANSPORT
END OF STROKE
PROXIMITY:CLOSED
TOWER LIFT
PROXIMITY:CLOSED
TOWER TELESCOPE
PROXIMITY:CLOSED
TOWER POSITION:
RETRACTED
CABLE BREAK
SWITCH: CLOSED
CREEP
SWITCH: CLOSED
CREEP MODE:
OFF
CHASSIS TILT:
XX.X DEGREES
Figure 6-6. Analyzer Software Version 6.8 - Sheet 2 of 6
– JLG Lift –
DIAGNOSTICS:
UMS
CHASSIS TILT
ANGLE: XX.X
UMS TO TURNTABLE
ANGLE: XX.X
UMS INCLINATION
ANGLE: XX.X
UMS STATUS:
CHASSIS TILT
NORMAL
X-AXIS: XX.X
CHASSIS TILT
Y-AXIS: XX.X
AUXILIARY POWER
SWITCH: OPEN
HORN
SWITCH: OPEN
RETURN HYDRAULIC
FILTER: OPEN
CHARGE PUMP
FILTER: OPEN
SOFT TOUCH LIMIT
SWITCH: OPEN
STOUCH OR SKYGRD
RELAYS: OPEN
ST/SG OVERRIDE
OVERRIDE: OPEN
GENSET.WELDER
SWITCH: OPEN
LIGHTS
SWITCH: OPEN
PLATFORM TILT1
ANGLE: XX.X
PLATFORM TILT2
ANGLE: XX.X
PLATFORM TILT1
VOLTAGE: XX MV
PLATFORM TILT2
VOLTAGE: XX MV
TO
DIAGNOSTICS:
LOAD
3121298