JLG 660SJ Service And Maintenance Manual page 276

Hide thumbs Also See for 660SJ:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Fault Flash
Communicated (Displayed on
Code
Analyzer) Fault
FUEL SENSOR SHORT TO
GROUND
4/4
BATTERY LOW
BATTERY TOO HIGH –
SYSTEM SHUT DOWN
BATTERY TOO LOW –
SYSTEM SHUT DOWN
5/5
SPEED SENSOR READING
INVALID SPEED
SPEED INPUT LOST
6/6
CAN BUS FAILURE:
7/7
9/9
PLATFORM MODULE
SOFTWARE UPDATE REQUIRED
HIGH RESOLUTION A2D
FAILURE –INTERRUPT LOST
HIGH RESOLUTION A2D
FAILURE-REINIT LIMIT
PLATFORM MODULE FAILURE:
HWFS CODE 1
GROUND MODULE FAILURE:
HWFS CODE 1
GROUND SENSOR REF
VOLTAGE OUT OF RANGE
PLATFORM SENSOR REF VOLT-
AGE OUT OF RANGE
EEPROM FAILURE – CHECK ALL
SETTINGS
CHASSIS TILT SENSOR NOT GAIN
CALIBRATED
CHASSIS TILT SENSOR GAIN OUT
OF RANGE
6-26
Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions
Indicates fuel sensor is reading below 0.2 volts.
Flash code 4/4 indicates problems with the battery supply. Not reported during
2 second power-up.
Battery voltage is below 11V for more than 5 seconds. This fault is not detected
during crank. This is a warning – controller does not shut down.
Battery voltage is above 16V. EMS recycle required.
Battery voltage is below 9V.
Flash code 5/5 indicates problems with vehicle engine RPM or the encoder. Not
reported during 2 second power-up.
This fault is detected with diesel engines only. The RPM pickup is indicating a
speed that greater than 4000 RPM or approximately 8875 Hz.
This fault is detected with diesel engines only. It occurs if there is no RPM
detected and the oil pressure input is reading above 8 PSI for more than three
seconds. This is probably due to wiring problems at the ground module or a
faulty speed sensor.
Flash code 6/6 indicates problems with the CAN bus.
Ground module or platform module is not receiving CAN messages. This is
probably due to wiring problems between the platform and ground modules.
Flash code 7/7 indicates problems with a motor.
NOT REQUIRED
Flash code 9/9 indicates problems with the controller.
Platform module code is too old to support the EIM or BPE load sensor and the
machine is configured to use one of these two sensors. The PM code must be
updated to a newer version.
The ADS1213 chip in the platform module has stopped asserting its interrupt
(DRDY) line for some reason. An EMS cycle is required.
The ADS1213 has needed to be reset 3 or more times.
Platform module V(Low) FET has failed
Ground module V(Low) FET has failed
These faults occur when the seven volt reference voltage used for joysticks, sen-
sors, etc. goes out of range. Not reported during 2 second power-up.
These faults occur when the seven volt reference voltage used for the joysticks,
sensors, etc. goes out of range. Not reported during 2 second power-up.
A critical failure occurred with the EEPROM. Personalities, machine configura-
tion digits, etc. may be reset to default values and should be checked.
Indicates that chassis tilt sensor calibration information has been lost. Machine
will indicate it is tilted at all times. This calibration data is programmed into the
unit at the factory.
Indicates chassis tilt sensor calibration is corrupted.
– JLG Lift –
Description
Priority
7
8
10
11
3121298

Advertisement

Table of Contents
loading

This manual is also suitable for:

600s