Event
Rebuild
Rebuild is started
Rebuild is completed
Rebuild is paused
Rebuild is resumed
Rebuild is stopped
Rebuild stopped internally The logical drive is offline. See page 286.
Rebuild is aborted due to
an internal error.
Rebuild is queued
Rebuild marks logical
drive synchronized upon
rebuild completion
Redundancy Check
Redundancy Check is
started
Redundancy Check is
completed
Redundancy Check is
paused
Redundancy Check is
resumed
Redundancy Check is
stopped
Redundancy Check is
aborted due to internal
error
Redundancy Check
encountered inconsistent
block(s)
Result of settings or user action. Normal.
Normal.
Rebuild paused because of user intervention,
schedule or a higher priority background activity.
Rebuild has resumed again after a pause.
Rebuild stopped because of user intervention,
schedule or the logical drive was deleted or the target
disk drive encountered an error. If rebuild stopped by
user intervention, restart the rebuild. See page 138.
System resources are low. Reduce system load or
restart the VTrak. See page 218.
Rebuild has been set manually or by schedule.
Result of successful rebuild. Normal.
Redundancy Check has started manually or by
schedule.
Redundancy Check has finished.
Redundancy Check paused because of user
intervention, schedule or a higher priority background
activity.
Redundancy Check has resumed again after a
pause.
Redundancy Check stopped because of user
intervention, schedule or the logical drive was deleted
or went critical or offline.
System resources are low. Reduce system load or
restart the VTrak. See page 218.
Check the logical drive's inconsistent block table. See
page 147. Rebuild the disk array if necessary.
page 138.