VTrak M-Class Product Manual
Event
Battery is charging
Battery reconditioning is
complete
Battery is malfunctioning
Battery reconditioned
successfully
Battery reconditioning has
failed
Battery is reaching end of
life
Battery is removed
Battery charging failed
Battery reconditioning
started
Battery recondition
terminated
Blowers
Blowers have started
Blowers have stopped
Blower speed is
increased
Blower speed is
decreased
Blowers are NOT
functioning
Blowers have been
inserted
Blowers have been
removed
Blowers are functioning
normally
Battery is being recharged.
Battery reconditioning is finished.
Run battery reconditioning. See page 121. If this
message reappears, replace the battery.
Battery reconditioning is finished.
Replace the battery. See page 230or page 233.
Replace the battery. See page 230or page 233.
The battery was disconnected or removed. Reinstall
the battery. See page 230or page 233.
Replace the battery. See page 230or page 233.
Battery reconditioning has begun.
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 230or
page 233.
Normal.
Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers. See
page 221 or page 226.
Check the VTrak for overheating. See page 289.
Temporary overheat condition was corrected.
Replace the blowers. See page 221 or page 226.
Normal.
Reinstall the cooling unit(s). If the blowers does not
turn, replace the blowers. See page 221 or page 226.
Normal.