Event
Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not
Blower status is unknown Check for airflow out of the cooling unit. If there is
Cache
BBU flushing has started VTrak's cache is being flushed.
BBU flushing has ended
BBU flushing has failed
Controller
The controller
parameter(s) changed by
user
The controller has new
crash information
Controller temperature is
above the threshold/
warning threshold
Controller temperature is
above the critical
threshold
Disk Array
New disk array has been
created
Disk array has been
deleted
Disk array has been
added
Disk array has been
removed
Disk array settings have
been changed
Drive Interface Controller
Drive-interface controller
found
turn, replace the blowers. See page 221 or page 226.
none, check for proper installation.
VTrak's cache has been flushed.
VTrak's cache could not be flush. Check your cache
flush interval setting. See page 116.
The user successfully change controller settings. See
page 116.
Check the event logs. See page 70.
The VTrak controller is overheating. Check for airflow
around and through the controller, and verify that all
fans are working. Replace fans as needed.
The VTrak controller is seriously overheating. Check
for airflow around and through the controller, and
verify that all fans are working. Replace fans as
needed.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
The physical drives of the disk array were removed
from the enclosure.
The user successfully logical drive settings. See
page 135.
Normal.
273
Chapter 8: Troubleshooting