Event
PSU fan speed increased. Check the VTrak for overheating. See page 289.
PSU fan speed
decreased.
PSU fan is malfunctioning Replace the power supply. See page 220.
PSU fan is functioning
normally
PSU fan status is
unknown.
RAID Level Migration
RAID Level migration is
started
RAID Level migration is
completed
RAID Level migration is
paused
RAID Level migration is
resumed
RAID Level migration is
stopped
RAID Level migration has
encountered a physical
disk error
RAID Level migration is
aborted due to an internal
error.
RAID Level migration is
queued
Migration has detected/
cleared stale NV
Watermark
Array was incomplete due
to missing NV Watermark
Temporary overheat condition was corrected.
Normal.
Check for airflow out of the power supply. If there is
none, check for proper installation and turn the power
supply on.
Result of settings or user action. Normal.
Normal.
Migration paused because of user intervention,
schedule or a higher priority background activity.
Migration has resumed again after a pause.
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 147.
System resources are low. Reduce system load or
restart the VTrak. See page 218.
Migration has been set manually or by schedule.
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
RAID migration was interrupted by a shutdown. If
array is online, try migration again. See page 137. If
array is offline, delete and recreate array. See
page 132 and page 131.
281