Replace Cache Battery – M300f/i/p and M200f/i/p
The cache battery is located in the Cooling Unit. The battery is replaced as an
individual part. No tools are required for this procedure.
To replace a cache battery, do the following:.
Battery LED
1.
Verify that the battery LED is amber or red (above).
2.
Power down the VTrak.
3.
Grasp the cooling unit handle and pull it toward you, as shown above.
4.
Pull the cooling unit out of the VTrak enclosure.
Try reconditioning the battery before you replace it. See
"Battery" on page 120 for more information.
The Cooling Unit is NOT a hot-swappable device. Power-
down the VTrak before removing it.
Installing an incorrect replacement battery may result in an
explosion.
Dispose of used batteries according to the instructions that
accompany the battery.
If power service has failed, do not remove the cooling unit if
the Controller's Dirty Cache LED is flashing. See "Unsaved
Data in the Controller Cache" on page 295.
Cautions