Promise Technology VTrack M-Class M200f Product Manual page 287

Promise technology vtrak m-class product manual
Table of Contents

Advertisement

Event
Physical disk is marked
online
Physical disk is marked
as dead.
Physical disk has been
reset
Physical disk assigned as
global spare
Physical disk is no longer
assigned as global spare
Physical disk assigned as
dedicated spare
Physical disk is no longer
assigned as dedicated
spare
Physical disk has been
inserted
Physical disk has been
removed
Bad sector is found on
physical disk
Error is detected in remap
sectors
Command times out on
physical drive
Physical disk negotiation
speed is decreased.
Previously configured disk
is no longer found
A physical disk has
encountered an unknown
(non-ECC) media error.
Disk drive removed from service due to errors. If
necessary, try to force the disk online. See page 127
or page 181.
Disk drive failure. Replace the disk drive. See
page 16.
Disk drive reset after error and should function
normally.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
A disk drive has been inserted into the VTrak
subsystem.
A disk drive has been removed from the VTrak
subsystem.
Disk drive has a bad sector. The drive should remap
around the bad sector. If this message appears
repeatedly, replace the disk drive.
Disk drive has a bad remap sectors. If this message
appears repeatedly, replace the disk drive.
Disk drive not responding to commands. If this
message appears repeatedly, replace the disk drive.
Disk drive had to reduce its data rate. If this message
appears repeatedly, replace the disk drive.
Disk drive may have failed or was removed from the
enclosure. Replace or reinstall the disk drive as
needed.
Disk drive experienced an unknown error. If this
message appears repeatedly, replace the disk drive.
279
Chapter 8: Troubleshooting
Action

Advertisement

Table of Contents
loading

Table of Contents