Enclosure - Promise Technology VTrack M-Class M200f Product Manual

Promise technology vtrak m-class product manual
Table of Contents

Advertisement

Enclosure

Enclosure Information
The Enclosure–Information tab provides a diagram showing the status and
location of key components. Status information about the VTrak subsystem
enclosure, including:
SEP Firmware Version
Polling Interval*
Enclosure Warning and Critical temperature thresholds*
Controller Warning and Critical temperature thresholds*
Power Supply Units – Device ID, Status, Fan status, and Fan speed
Blowers (scroll fans in the cooling unit(s) – Device ID, Status, and Speed
Voltage Sensors – 3.3V, 5.0V, and 12.0V
Temperature Sensors – The number of sensors varies among VTrak models
To access Controller information:
1.
Click the Subsystem
2.
Click on the Enclosures
3.
Click on the Enclosure
For information on Enclosure problems, see "Chapter 8: Troubleshooting" on
page 261.
Enclosure Settings
The Enclosure–Settings tab enables you to make settings for certain components
of the VTrak subsystem enclosure. To make Enclosure settings:
1.
Click the Subsystem
2.
Click on the Enclosures
3.
Click on the Enclosure
4.
Click on the Settings tab in Management View.
5.
Enter a polling interval (15 to 255 seconds) in the Polling Interval field.
6.
Enter a value in the Enclosure Warning Temperature Threshold field (45°C is
the default).
7.
Enter a value in the Enclosure Critical Temperature Threshold field (51°C is
the default).
8.
Enter a value in the Controller Warning Temperature Threshold field (63°C is
the default).
9.
Enter a value in the Controller Critical Temperature Threshold field (68°C is
the default).
Chapter 4: Management with WebPAM PROe
icon in Tree View.
icon.
icon.
icon in Tree View.
icon.
icon.
119