21 TROUBLESHOOTING
Faults
Battery discharged
Combination instrument values
deleted (time, stop watch, lap
times)
The high beam, low beam, tail
light, parking light, and license
plate lamp are not working
Combination instrument, horn,
brake light, turn signal, and
radiator fan are not working
140
Possible cause
Battery is not being charged
by alternator
Undesired power consumer
The battery in the combination
instrument is discharged
Fuse 2 blown
Fuse 3 blown
Action
Check the charging voltage.
Check the stator winding of the alter-
nator.
Check the closed current.
Change the combination instrument.
(
p. 117)
Change the fuses of individual power
consumers. (
p. 111)
Change the fuses of individual power
consumers. (
p. 111)