Function
Ignition off Timeout
(secs)
Low supply timeout
(secs)
Minimum operating
supply (volts)
Nominal operating
supply (volts)
Power Management
Enabled
Remote Set / Unset
This page is used to set or unset the system remotely for a period of time. This remote set will overwrite the
current state of the system until the specified duration is exceeded OR there is a set / unset event local to the
site (i.e. keyswitch / keypad). If the system is set by timer, a change in state from the timer will not override
the remote set state.
Advanced Features
The TransVu supports a number of advanced features, each of these can be enabled or disabled depending
on what the system requirements are.
Enabling the features in this menu will display the corresponding configuration pages.
50
Description
The ignition off timeout specifies how long the TransVu will continue to operate after
the ignition input is switched off.
The low supply timeout specifies how long the system should operate for after the
power supply drops below the specified low voltage threshold.
Typically this would be indicative of a weak battery.
The minimum operating voltage specifies the absolute minimum supply voltage at
which the system will power up.
The nominal operating voltage specifies the voltage at which the system enters the low
voltage timeout.
This option must be enabled if power management is required.
Dedicated Micros © 2006