P P o o w w e e r r M M a a n n a a g g e e m m e e n n t t We e b b p p a a g g e e
The TransVu power management is enabled on this page.
Ignition off Timeout (secs)
This is the time from when the ignition is switched off until the unit shuts itself down automatically. In the above
example 900 seconds = 15 minutes.
The ignition supply of the vehicle must be wired into alarm 5 for this feature to work. The input senses ignition
voltage above nine volts.
Low supply Timeout (secs)
When the voltage drops below the nominal operating supply setting (in the example, ten volts) the unit powers
down after the set time (30 secs in the example above).
If the voltage rises above the nominal setting the countdown is cancelled.
Minimum operating supply (volts)
This is the minimum voltage at which the unit will power up.
If the voltage drops below this level, the unit powers down immediately.
Nominal operating supply (volts)
When the voltage supply to the unit falls below this (user specified) level the unit powers down after the time set
for low supply timeout.
48
Dedicated Micros © 2006