Cleaning And Sanitizing Interior Surfaces (Monthly) - Cornelius SPIRE 4.1 Operator's Manual

Hide thumbs Also See for SPIRE 4.1:
Table of Contents

Advertisement

Cleaning and Sanitizing Interior Surfaces (Monthly)

While pouring liquid into the ice bin, do not exceed the rate of 1/2 gallon per minute. Pouring more
liquid into the bin could result in an overflow situation that may result in personal injury or damage to
!
the equipment.
CAUTION
Perform the following steps to clean the interior surfaces of the ice bin:
1. Open the display door and remove the
cover from the ice bin.
Avoid damage to the ice bin cover by put-
ting it in a safe place.
2. Remove the agitator retaining screw and
agitator cover.
To do this, turn the agitator retaining screw
counter-clockwise, then, lift the agitator
cover off the 2-piece agitator assembly.
3. Remove the 2-piece agitator assembly from
the bin shown Figure 24.
To do this, lift the first (top) piece of the 2-
piece agitator assembly from the bin, then
lift the second (bottom) piece out of the bin.
Result: See Figure 25.
© 2017, Cornelius Inc.
Display Door
Figure 22
Agitator
Retaining
Screw
Agitator
Cover
Figure 23
2-Piece
Agitator
Figure 24
- 17 -
Spire 4.1 Operator's Manual
Ice Bin Cover
Publication Number: 620066826OPR