Product Flavor Change; Checking Co2 Supply; Cleaning And Sanitizing; Daily Cleaning - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

1. To disconnect soft drink tank from Unit
syrup system.
A.
Disconnect liquid disconnect from soft drink tank. NOTE - Disconnecting liquid quick
disconnect from soft drink tank first prevents syrup from backflowing through Unit syrup flow
regulator, which may alter regulator adjustment.
B.
Second, disconnect CO
2. To connect soft drink tank into Unit syrup system.
A.
First, connect CO
B.
Second, connect liquid quick disconnect to soft drink tank.
Syrup supply should be checked daily and if necessary, replenished as instructed.

PRODUCT FLAVOR CHANGE

Perform syrup flavor change as instructed.
CHECKING CO
2
WARNING: CO
CO
(carbon dioxide) gas leaks in the entire CO
2
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
tremors which are followed rapidly by loss of consciousness and suffocation.
Make sure CO
cylinder shutoff valve is fully opened and regulator assembly 1800-psi gage indicator is not in
2
shaded (''change CO
cylinder'') portion of dial. If so, CO
2
instructed.

CLEANING AND SANITIZING

DAILY CLEANING

Daily or more often if necessary, wash all external surfaces of Unit, rinse with clean water, then wipe dry with
clean soft cloth. DO NOT USE ABRASIVE CLEANERS. Wash the drip tray and cup rest with warm water and
mild detergent, then rinse with clean water.

SANITIZING

The Unit syrup systems should be sanitized as instructed every 120-days and before and after storage periods
following parent company requirements and sanitizer manufacturers recommendations. Sanitize syrup systems
as instructed.

CLEANING CONDENSER COIL

The FCB Dispenser refrigeration system is equipped with a condenser coil (see Figure 6) that is cooled by two
condenser coil fans. Circulating air, required to cool the refrigeration system's condenser coil, is drawn in
through a grilled panel on the right-hand side and is exhausted out through the opposite side and back grilled
panels. Restricting air circulation through the Unit will decrease its cooling efficiency. THE CONDENSER COIL
MUST BE CLEANED PERIODICALLY AS INSTRUCTED IN the SERVICE AND MAINTENANCE section.

LUBRICATION

Carbonator pump motor must be lubricated as instructed on the motor.
quick disconnect from soft drink tank.
2
quick disconnect to soft drink tank to pressurize tank.
2
SUPPLY
displaces oxygen. Strict attention must be observed in the prevention of
2
and soft drink system. If a CO
2
cylinder is almost empty and must be replaced as
2
33
gas leak is
2
gas will experience
2