8. Clean the interior of the ice chute, using the brush
provided with the Clean the interior of the ice chute
using the brush provided with the unit or a nylon
bristle brush with a warm soap solution. Once clean,
rinse with clean water and wipe it to air dry.
Note: Pour any remaining warm soap solution down
the drain to help keep the drain clean and flowing
smoothly.
9. Then, spray the inside and outside of the ice chute with sanitizer and allow it to air dry.
10. Gather the clean valve nozzle components (valve nozzle housing, valve nozzle and diffuser) and spray
them with a sanitizing solution (see "Soap and Sanitizing Solutions" on page 13). Then, replace these com-
ponents back into the unit.
To replace these components back into the unit, do the following:
• ) First, make sure the diffuser gasket is seated properly and is in the correct position on top of the diffuser as
shown in Figure 19. Then, push the diffuser on to the nozzle base so that the diffuser gasket is against the
nozzle base. See Figure 17.
• ) With the diffuser in place, place the valve nozzle in the valve nozzle housing so that the notches in the valve
nozzle line up with the tabs of the housing. See Figure 15 and Figure 16, above.
• ) Finally, place the valve nozzle housing (with the valve nozzle inside) over nozzle base (shown in Figure 17)
and turn the housing approximately 1/4 turn (counter-clockwise) to secure the housing to the nozzle base.
Diffuser Gasket
with tabs linked
up properly.
11. Reinstall the ice slide.
12. Pour all the remaining sanitizer solution down the drain to help keep the drain clear.
W
M
EEKLY
AINTENANCE
Check the following items weekly to maintain the unit in proper condition.
• ) Temperature, smell and taste of the product.
• ) Water pressure [60 - 65 psi,
package.
• ) Carbonation of the drink.
• ) Level of the CO
• ) Date on all of the BIBs in the back room package.
© 2017, Cornelius Inc.
Diffuser
(installed)
coming to the unit using the pressure gauge on the back room
(0.45 MPa)],
cylinder in the back room supplying the unit.
2
Figure 19
- 15 -
Spire 4.1 Operator's Manual
Figure 18
Publication Number: 620066826OPR

Advertisement

Table of Contents
loading

Table of Contents