Reference
Information
This section contains mounting information.
Mounting
The XTP T USW 103 can be placed on a tabletop or mounted in a rack or underneath a
desk.
Tabletop Mounting
Attach the provided rubber feet to the bottom four corners of the enclosure.
Furniture Mounting
Go to
device to furniture, follow the mounting kit instructions.
Rack Mounting
Go to
to a rack, follow the mounting kit instructions and see the UL guidelines for rack-mounted
devices below.
UL guidelines for rack-mounted devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
XTP T USW 103 in a rack.
1.
2.
3.
4.
5.
www.extron.com
for a list of compatible furniture mounting kits. To install either
www.extron.com
for a list of compatible furniture mounting kits. To install the device
Elevated operating ambient temperature — If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature, Therefore, install the XTP T USW 103 in an
environment compatible with the maximum ambient temperature (Tma = +122 ˚F, +50
˚C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have an overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (for example, the use of power strips).
XTP T USW 103 Switcher • Reference Information
37