Reference Information; Mounting The Sw Usb Pro Series Switcher; Tabletop Use; Ul Rack Mounting Guidelines - Extron electronics SW USB Pro Series User Manual

Usb switchers
Hide thumbs Also See for SW USB Pro Series:
Table of Contents

Advertisement

Reference
Information
This section provides reference information on the SW USB Pro Series. The following topics
are covered:

Mounting the SW USB Pro Series Switcher

The SW USB Pro Series switcher can be set on a table, mounted on a rack shelf, or
mounted under a desk, podium, or table.

Tabletop Use

Four adhesive rubber feet are included with the SW USB Pro switcher. For tabletop use,
attach one foot at each corner on the bottom of the unit, and place the switcher in the
desired location.

UL Rack Mounting Guidelines

The SW USB Pro units can be mounted on a 9.5-inch, 6-inch, or 3.5-inch deep rack shelf.
They can also be mounted vertically to the front or back rack support. Rack mounting kits
are available at www.extron.com. For mounting procedures, see the instructions provided
with the rack mounting kit. The following Underwriters Laboratories (UL) guidelines pertain to
the safe installation of the SW USB Pro enclosure in a rack.
CAUTION:
Mounting the SW USB Pro Series Switcher
Downloading Updated Firmware
Elevated operating ambient temperature — If the equipment is installed in
a closed or multi-unit rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient temperature. Therefore,
install the equipment in an environment compatible with the maximum ambient
temperature (TMA = +122 °F, +50 °C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air
flow required for safe operation of the equipment is not compromised.
Mechanical loading — When mounting the equipment in the rack, ensure that
uneven mechanical loading does not cause a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit,
consider the effect that circuit overloading might have on overcurrent protection
and supply wiring. Consider equipment nameplate ratings when addressing this
concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct
connections to the branch circuit (for example, use of power strips).
SW USB Pro Series • Reference Information
38