Replace The Tubing In The Peristaltic Pump - 3D Systems ProX 800 User Manual

Hide thumbs Also See for ProX 800:
Table of Contents

Advertisement

Replace the Tubing in the Parastaltic Pump
If the tubing for the pump becomes damaged or clogged, you can replace it using the following procedure.
Tools Needed:
Paper towels
Wire tie snips
Wire (zip) ties
Nitrile gloves
Flathead screwdriver
Receptacle to catch excess print material from tubing (i.e., a Tupperware container)
Procedure:
1. Note the routing of the hose on the MDM. You will need to reinstall it as it exists on your MDM. The routing of your hose
may differ from some of the pictures below.
2. Tighten the reservoir connection valve (1) by turning it clockwise to stop the flow of print material.
3. Loosen the two hose clamps from the valves using a flathead screwdriver. (2)
2
MDM Showing Pump Tubing
3D Systems, Inc.
MDM Pump
Connection
Peristaltic
Pump
Pump
Tubing
Leveling Reservoir
Pump Connection
68
1
2
Hose clamp
2