GE L60 Instruction Manual page 469

Line phase comparison relay, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 24 of 51)
ADDR
REGISTER NAME
68AF
Autoreclose Transfer Time
68B0
Autoreclose Event
68B1
Autoreclose 3P Dead Time 3
68B2
Autoreclose 3P Dead Time 4
68B3
Autoreclose Bus FLT Init
68B3
Reserved (14 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7007
Phase Undervoltage 1 Target
7008
Phase Undervoltage 1 Events
7009
Phase Undervoltage 1 Measurement Mode
700A
Reserved (6 items)
7013
...Repeated for Phase Undervoltage 2
Phase Overvoltage (Read/Write Grouped Setting)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
7046
Phase Overvoltage 1 Target
7047
Phase Overvoltage 1 Events
7048
Reserved (8 items)
Distance (Read/Write Grouped Setting)
7060
Distance Signal Source
7061
Memory Duration
7062
Force Self-Polarization
7062
Force Memory Polarization
Phase Distance (Read/Write Grouped Setting) (5 modules)
7070
Phase Distance Zone 1 Function
7071
Phase Distance Zone 1 Current Supervision
7072
Phase Distance Zone 1 Reach
7073
Phase Distance Zone 1 Direction
7074
Phase Distance Zone 1 Comparator Limit
7075
Phase Distance Zone 1 Delay
7076
Phase Distance Zone 1 Block
7077
Phase Distance Zone 1 Target
7078
Phase Distance Zone 1 Events
7079
Phase Distance Zone 1 Shape
707A
Phase Distance Zone 1 RCA
707B
Phase Distance Zone 1 DIR RCA
707C
Phase Distance Zone 1 DIR Comp Limit
707D
Phase Distance Zone 1 Quad Right Blinder
707E
Phase Distance Zone 1 Quad Right Blinder RCA
707F
Phase Distance Zone 1 Quad Left Blinder
7080
Phase Distance Zone 1 Quad Left Blinder RCA
7081
Phase Distance Zone 1 Volt Limit
7082
Phase Distance Zone 1 Transformer Voltage Connection
GE Multilin
RANGE
0 to 655.35
0 to 1
0 to 655.35
0 to 655.35
0 to 65535
---
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 5
5 to 25
0 to 65535
0 to 65535
0 to 1
0.05 to 30
0.02 to 500
0 to 2
30 to 90
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 1
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 5
0 to 12
L60 Line Phase Comparison Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
0.01
F001
---
1
F102
s
0.01
F001
s
0.01
F001
s
0.01
F300
---
---
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
cycles
1
F001
---
1
F300
---
1
F300
---
1
F102
pu
0.001
F001
ohms
0.01
F001
---
1
F154
degrees
1
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F120
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
pu
0.001
F001
---
1
F153
DEFAULT
400
0 (Disabled)
200
400
0
B
0
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
10
0
0
0 (Disabled)
200
200
0 (Forward)
90
0
0
0 (Self-reset)
0 (Disabled)
0 (Mho)
85
85
90
1000
85
1000
85
0
0 (None)
B-31