GE L60 Instruction Manual page 448

Line phase comparison relay, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 51)
ADDR
REGISTER NAME
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
Element Targets (Read Only)
B
14C0
Target Sequence
14C1
Number of Targets
Element Targets (Read/Write)
14C2
Target to Read
Element Targets (Read Only)
14C3
Target Message
Digital Input/Output States (Read Only)
1500
Contact Input States (6 items)
1508
Virtual Input States (8 items)
1510
Contact Output States (4 items)
1518
Contact Output Current States (4 items)
1520
Contact Output Voltage States (4 items)
1528
Virtual Output States (6 items)
1530
Contact Output Detectors (4 items)
Remote Input/Output States (Read Only)
1540
Remote Device 1 States
1542
Remote Input States (4 items)
1550
Remote Devices Online
Remote Device Status (Read Only) (16 modules)
1551
Remote Device 1 StNum
1553
Remote Device 1 SqNum
1555
...Repeated for Remote Device 2
1559
...Repeated for Remote Device 3
155D
...Repeated for Remote Device 4
1561
...Repeated for Remote Device 5
1565
...Repeated for Remote Device 6
1569
...Repeated for Remote Device 7
156D
...Repeated for Remote Device 8
1571
...Repeated for Remote Device 9
1575
...Repeated for Remote Device 10
1579
...Repeated for Remote Device 11
157D
...Repeated for Remote Device 12
1581
...Repeated for Remote Device 13
1585
...Repeated for Remote Device 14
1589
...Repeated for Remote Device 15
158D
...Repeated for Remote Device 16
Platform Direct Input/Output States (Read Only)
15C0
Direct input states (6 items)
15C8
Direct outputs average message return time 1
15C9
Direct outputs average message return time 2
15CA
Direct inputs/outputs unreturned message count - Ch. 1
15CB
Direct inputs/outputs unreturned message count - Ch. 2
15D0
Direct device states
15D1
Reserved
15D2
Direct inputs/outputs CRC fail count 1
15D3
Direct inputs/outputs CRC fail count 2
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet primary fibre channel status
1611
Ethernet secondary fibre channel status
B-10
RANGE
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
L60 Line Phase Comparison Relay
APPENDIX B
UNITS
STEP
FORMAT
---
---
F200
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F200
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F126
---
1
F003
---
1
F003
---
1
F500
ms
1
F001
ms
1
F001
---
1
F001
---
1
F001
---
1
F500
---
1
F001
---
1
F001
---
1
F001
---
1
F134
---
1
F134
DEFAULT
(none)
0
0
0
0
"."
0
0
0
0
0
0
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
GE Multilin