B.4 MEMORY MAPPING
bitmask
element
60
Negative Sequence Directional Overcurrent 1
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
66
Ground Instantaneous Overcurrent 3
67
Ground Instantaneous Overcurrent 4
B
68
Ground Instantaneous Overcurrent 5
69
Ground Instantaneous Overcurrent 6
70
Ground Instantaneous Overcurrent 7
71
Ground Instantaneous Overcurrent 8
72
Ground Instantaneous Overcurrent 9
73
Ground Instantaneous Overcurrent 10
74
Ground Instantaneous Overcurrent 11
75
Ground Instantaneous Overcurrent 12
80
Ground Time Overcurrent 1
81
Ground Time Overcurrent 2
82
Ground Time Overcurrent 3
83
Ground Time Overcurrent 4
84
Ground Time Overcurrent 5
85
Ground Time Overcurrent 6
96
Negative Sequence Instantaneous Overcurrent 1
97
Negative Sequence Instantaneous Overcurrent 2
101
Opposite Phase Rotation
112
Negative Sequence Time Overcurrent 1
113
Negative Sequence Time Overcurrent 2
120
Negative Sequence Overvoltage
121
Wattmetric Zero-Sequence Directional 1
122
Wattmetric Zero-Sequence Directional 2
140
Auxiliary Undervoltage 1
144
Phase Undervoltage 1
145
Phase Undervoltage 2
148
Auxiliary Overvoltage 1
152
Phase Overvoltage 1
156
Neutral Overvoltage 1
161
Phase Distance Zone 2
168
Line Pickup
180
Load Enchroachment
185
PUTT Pilot Scheme
190
Power Swing Detect
224
SRC1 VT Fuse Failure
225
SRC2 VT Fuse Failure
226
SRC3 VT Fuse Failure
227
SRC4 VT Fuse Failure
228
SRC5 VT Fuse Failure
229
SRC6 VT Fuse Failure
232
SRC1 50DD (Disturbance Detection)
233
SRC2 50DD (Disturbance Detection)
234
SRC3 50DD (Disturbance Detection)
235
SRC4 50DD (Disturbance Detection)
245
Continuous Monitor
246
CT Failure
272
Breaker 1
273
Breaker 2
B-62
bitmask
280
281
288
289
290
291
292
293
294
295
304
305
306
307
308
309
312
313
336
337
360
362
375
382
383
384
385
386
388
389
390
391
392
393
394
395
396
400
401
402
403
404
405
406
407
420
421
422
423
424
425
426
427
L60 Line Phase Comparison Relay
element
Breaker Failure 1
Breaker Failure 2
Breaker Arcing Current 1
Breaker Arcing Current 2
Breaker Arcing Current 3
Breaker Arcing Current 4
Breaker Arcing Current 5
Breaker Arcing Current 6
Breaker 1 Flashover
Breaker 2 Flashover
Autoreclose 1
Autoreclose 2
Autoreclose 3
Autoreclose 4
Autoreclose 5
Autoreclose 6
Synchrocheck 1
Synchrocheck 2
Setting Group
Reset
Trip Output
Phase Selector
Autoreclose
87PC channel test
87PC phase comparison trip
87PC negative-sequence voltage fault detector
87PC negative-sequence current rate of change
87PC positive-sequence current rate of change
Selector 1
Selector 2
Control pushbutton 1
Control pushbutton 2
Control pushbutton 3
Control pushbutton 4
Control pushbutton 5
Control pushbutton 6
Control pushbutton 7
FlexElement™ 1
FlexElement™ 2
FlexElement™ 3
FlexElement™ 4
FlexElement™ 5
FlexElement™ 6
FlexElement™ 7
FlexElement™ 8
Non-volatile Latch 1
Non-volatile Latch 2
Non-volatile Latch 3
Non-volatile Latch 4
Non-volatile Latch 5
Non-volatile Latch 6
Non-volatile Latch 7
Non-volatile Latch 8
APPENDIX B