5.2.4 current sensors

5.2.4.1 Precautions for use

Refer to the safety sheet or user manual that was supplied with your current sensors for more information.

5.2.4.2 use and characteristics

Current clamps and flexible current sensors are used to measure the current flowing in a cable without opening the circuit.
They also insulate the user from dangerous voltages in the circuit.
The choice of current sensor to be used depends on the current to be measured and the diameter of the cables.
When installing current sensors, face the arrow on the probe or the sensor in the direction of the load.
5.2.4.3 Miniflex
®
The Flexible Current Sensor MiniFlex
the circuit. It also serves to isolate the user from hazardous voltages in the circuit. This sensor can only be used as an
accessory of an instrument. Before connecting it, if you have several sensors, you can mark each of them using one of
the color-coded ID markers supplied with the instrument to identify the phase. Then connect the sensor to the instrument.
Press the yellow opening device to open the Flexible coil. Then, place it around the conductor through which the
current to be measured flows (only one conductor in the sensor).
Close the coil. In order to optimize measurement quality, it is best to center the conductor in the coil and make
the shape of the coil as circular as possible.
To disconnect the coil, open it and withdraw it from the conductor. Then, disconnect the sensor from the
instrument.
Nominal Range
Measurement Range
Sensor
Safety
NOTE: Currents < 0.05% of the nominal range (100, 400, 2000 or 10000A) will be displayed as zero.
The nominal ranges are reduced to 50/200/1000/5000A

5.2.4.4 other current sensors

The measurement ranges are those of the sensors. In some cases, they may differ from the ranges that can be measured
by the PEL. For use, see the manual distributed with the current sensor
NOTE: Power calculations will be zeroed when the current is zeroed.
Nominal Range
Measurement Range
Maximum Clamping Diameter
Safety
NOTE: Currents < 1A
Nominal Range
Measurement Range
Maximum Clamping Diameter
Safety
NOTE: Currents < 0.5A will be displayed as zero.
74
Find Quality Products Online at:
Ma193
Model MA193 can be used to measure the current in a cable without opening
®
100/400/2000/10000A
50mA to 12000A
Length = 10" (250 mm); Ø = 2.75" (70 mm)
EN 61010-2-032, Pollution Degree 2, 600V CAT IV, 1000V CAT III
1000A
, 1400A
AC
10 to 1000A
AC
One 1.6" (42mm) or two 0.98" (25.4mm) or two bus bars 1.96 x 0.19" (50 x 5mm)
EN 61010-2-032, Pollution Degree 2, 300V CAT IV, 600V CAT III
will be displayed as zero.
AC/DC
for f ≤1 kHz
1000A
AC
1 to 1200A
AC
2" (52mm)
EN 61010-2-032, Pollution Degree 2, 600V CAT IV, 1000V CAT III
GlobalTestSupply
www.
MiniFlex
MA193
®
AC
AC
at 400Hz.
AC
Table 16
Model MR193
max
DC
, 10 to 1300A
PEAK AC+DC
Table 17
Model SR193
max (I >1000A not continuously)
Table 18
Power & Energy Logger Model PEL 102 and PEL 103
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pel103Pel 102

Table of Contents