HEIDENHAIN TNC 620 User Manual page 417

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

Touch Probe Cycles: Automatic Presetting | PRESET AT CENTER OF 4 HOLES (Cycle 418, DIN/ISO: G418,
software option 17)
Q331 New preset in reference axis? (absolute):
Coordinate in the reference axis at which the TNC
should set the intersection of the connecting lines.
Default setting = 0. Input range -99999.9999 to
99999.9999
Q332 New preset in minor axis? (absolute):
Coordinate in the minor axis at which the TNC
should set the intersection of the connecting lines.
Default setting = 0. Input range -99999.9999 to
99999.9999
Q303 Meas. value transfer (0,1)?: Specify
whether the determined preset is to be saved in
the datum table or in the preset table:
-1: Do not use! Is entered by the TNC when
old programs are read in (see "Characteristics
common to all touch probe cycles for presetting",
Page 370)
0: Write the measured preset into the active
datum table. The reference system is the active
workpiece coordinate system
1: Write the measured preset into the preset table.
The reference system is the machine coordinate
system (REF system).
Q381 Probe in TS axis? (0/1): Specify whether
the TNC should also set the preset in the touch
probe axis:
0: Do not set the preset in the touch probe axis
1: Set the preset in the touch probe axis
Q382 Probe TS axis: Coord. 1st axis? (absolute):
Coordinate of the probe point in the reference axis
of the working plane at which point the preset is
to be set in the touch probe axis. Only effective if
Q381 = 1. Input range -99999.9999 to 99999.9999
Q383 Probe TS axis: Coord. 2nd axis? (absolute):
Coordinate of the probe point in the minor axis
of the working plane at which point the preset is
to be set in the touch probe axis. Only effective if
Q381 = 1. Input range -99999.9999 to 99999.9999
Q384 Probe TS axis: Coord. 3rd axis? (absolute):
Coordinate of the probe point in the touch probe
axis, at which point the preset is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999
Q333 New preset in TS axis? (absolute):
Coordinate in the touch probe axis at which the
TNC should set the preset. Default setting = 0.
Input range -99999.9999 to 99999.9999