Touch Probe Cycles: Automatic Kinematics Measurement | PRESET COMPENSATION (Cycle 452, DIN/
ISO: G452, option)

Adjustment of interchangeable heads

The goal of this procedure is for the workpiece preset to remain
unchanged after changing rotary axes (head exchange).
In the following example, a fork head is adjusted to the A and C axes.
The A axis is changed, whereas the C axis continues being a part of
the basic configuration.
Insert the interchangeable head that will be used as a reference
head.
Clamp the calibration sphere
Insert the touch probe
Use Cycle 451 to measure the complete kinematics, including the
reference head.
Set the preset (using Q431 = 2 or 3 in Cycle 451) after measuring
the reference head
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 10/2017
Measuring a reference head
1 TOOL CALL "TCH PROBE" Z
2 TCH PROBE 451 MEASURE KINEMATICS
Q406=1
;MODE
Q407=12.5
;SPHERE RADIUS
Q320=0
;SET-UP CLEARANCE
Q408=0
;RETR. HEIGHT
Q253=2000
;F PRE-POSITIONING
Q380=+45
;REFERENCE ANGLE
Q411=-90
;START ANGLE A AXIS
Q412=+90
;END ANGLE A AXIS
Q413=45
;INCID. ANGLE A AXIS
Q414=4
;MEAS. POINTS A AXIS
Q415=-90
;START ANGLE B AXIS
Q416=+90
;END ANGLE B AXIS
Q417=0
;INCID. ANGLE B AXIS
Q418=2
;MEAS. POINTS B AXIS
Q419=+90
;START ANGLE C AXIS
Q420=+270
;END ANGLE C AXIS
Q421=0
;INCID. ANGLE C AXIS
Q422=3
;MEAS. POINTS C AXIS
Q423=4
;NO. OF PROBE POINTS
Q431=3
;PRESET
Q432=0
;BACKLASH, ANG. RANGE