3 CLEARANCES TO COMBUSTIBLE MATERIALS

The clearances shown in this section have been determined by tests according to procedures set out
in safety standards ULC S627 (Canada), ASTM E1509 (U.S.A) and UL1482 (USA). When the pellet stove
is installed so that its surfaces are at, or beyond, the minimum clearances specified, combustible
surfaces will not overheat under normal and even abnormal operating conditions.
• NO PART OF THE STOVE MAY BE LOCATED CLOSER TO COMBUSTIBLES THAN THE MINIMUM
CLEARANCES SPECIFIED ON THE CERTIFICATION LABEL.
NO PART OF THE PELLET VENT SYSTEM MAY BE LOCATED CLOSER TO COMBUSTIBLES THAN
THE MINIMUM CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
DO NOT USE MAKESHIFT MATERIALS OR MAKE ANY COMPROMISES WHEN INSTALLING THIS
STOVE.

3.1 Certification Label Location

Since the information given on the certification label affixed to the stove always overrides the
information published in any other media (owner's manual, catalogues, flyers, magazines and/or web
sites), it is important to refer to it in order to have a safe and compliant installation. In addition, you
will find important information about your stove (model, serial number, etc.). You will find the
certification label on the inner side of the hopper lid of the stove.

3.2 Clearances to combustibles materials, walls and ceiling

The distances listed in this table refer to the distances obtained during regular testing. However, it is
possible to install the stove at reduced clearances by installing either a certified heat shield system
(AC02710) or a side clearance reduction kit (AC02733), sold separately.
12
WARNING
CAUTION
MINIMUM CLEARANCES
LETTER
*
A
3" (76 mm)
D
**
I
48" (1 220 mm)
*
From the rear panel
**
Measured from the platform on which the product is
installed.
RECOMMENDED CLEARANCES
LETTER
*
A
12" (305 mm)
Cambridge Pellet Stove Installation and Operation Manual
CANADA
USA
3" (76 mm)
Note 1
Note 1
48" (1 220 mm)
CANADA
USA
12" (305 mm)
2