Installation; Eurozone Freestanding Pellet Stove; Preparation; Clearances - Enerzone EUROZONE Owner's Manual

Table of Contents

Advertisement

INSTALLATION

EUROZONE FREESTANDING PELLET STOVE

Width: 25"
Height: 34¾"
Depth: 25¼"
Weight: 320 lbs.
Flue size: 3" or 4"
Hopper Capacity: Up to 80 lbs.
(This can vary slightly depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1.3 lbs to 4.1 lbs. per hour
BTU range: 8,200 to 35000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional

PREPARATION

Factory packaging must be removed, and some minor assembly work is
required prior to installation:
The door overlay must be installed on the door frame;
The black knob must be attached to the heat exchanger rod;
Filters may be inserted between the finger guards and the
convection blowers (see "filters assembly" section).

CLEARANCES

The EUROZONE has been tested and listed for installation in regular and
mobile homes.(refer figure 1 & 2)
FLOOR PROTECTION: In the USA, the unit must be installed on a non-
combustible floor pad extending at least 6 inches (155 mm) in front of the
door opening and at least 6 inches (155 mm) on each side of the door
opening. In Canada, the unit must be installed on a noncombustible floor
pad extending at least 18 inches (460 mm) in front of the door opening and
at least 8 inches (205 mm) at the back and on each side of the unit. The
floor pad must have a thickness of at least 0.015'' (0.38mm). NOTE:
ceramic tile, or any tile, must be laid on a continuous non combustible
sheet to prevent the possibility of embers falling through to the combustible
floor if cracks or separation should occur in the finished surface.
Clearances are measured from the sides, back and face (door opening) or
stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
This heating unit must serve as a supplementary heat source. An alternative heat source
should be available in the home if needed. The manufacturer cannot be responsible for
additional heating costs associated with the use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide
installation and maintenance advices.
Back wall installation
Figure 2
Corner installation Floor protection
CLEARANCES TO COMBUSTIBLES
CANADA
A
2'' (55 mm)
B
6'' (155 mm)
2'' (55 mm)
C
D
3'' (80 mm)
FLOOR PROTECTION
CANADA
E
18'' (460 mm)
F
N/A (USA only)
G
8'' (205 mm)
H
8'' (205 mm)
We recommend leaving 24'' on each sides of the appliance in order to
facilitate access for maintenance.
6
Figure 1
 
Ouverture
de porte 
Figure 3
USA
2'' (55 mm)
6'' (155 mm)
2'' (55 mm)
3'' (80 mm)
USA
6'' (155 mm)
6'' (155 mm)
N/A (Canada only)
N/A (Canada only)