8.1.3 Exhaust Channel and Exhaust Blower Maintenance

Exhaust channel is accessible from the front and the exhaust blower is located on left hand side of the
stove. The following procedure demonstrates how to perform inspection and cleaning:
In order to access the exhaust channel removed the ash drawer access panel (A) and the ash drawer
(B). Then remove the exhaust channel plug (C).