Hopper Lid Open - Enerzone Cambridge EP00075 Installation And Operation Manual

Table of Contents

Advertisement

NOTE: IF THE CODE APPEARS MORE THAN THREE TIMES, THE LCD SCREEN WILL LOCK ITSELF UP.
THIS PELLET STOVE IS EQUIPED WITH MULTIPLE DEVICES TO ENSURE YOUR SAFETY. IF A WARNING
ERROR CODE STOPS YOUR STOVE ON SEVERAL OCCASIONS, IT IS MORE THAN LIKELY THAT THE
STOVE DOES NOT EXHAUST PROPERLY.
Before resetting the PC-board displaying an error code, do a
COMPLETE stove maintenance as described in this manual.
For an Overheat Code
Service the stove COMPLETELY as described in this manual. See section 8:
Maintenance.
Verify the venting system and all other components mentioned above.
ONCE THE MAINTENANCE DONE, FOLLOW THESE INSTRUCTIONS
After 3 attempts, press restart
999333555

9.3.7 Hopper Lid Open

The hopper lid remained open for more than 3 minutes. As a security measure, the auger stops
turning and feeding pellets as soon as the hopper lid opens. It will resume normal operation as
soon as the hopper lid is closed. If the hopper lid stays open for more than 3 minutes, the stove
will stop.
The hopper lid safety switch is faulty or disconnected. Make sure that the switch wiring is
properly connected. If it is, the hopper switch may be faulty. Follow steps in the troubleshooting
page (see Section 9.2 Testing Components) and verify the proper function of the safety switch.
Replace if necessary.
Cambridge Pellet Stove Installation and Operation Manual
and press accept. The system will reset.
and then enter the following code
61