Editing Saved Data
The following explain how to modify the data which is saved in FD/PC
CARD on PC.
<Data Example>
//IFPANEL 1
//NAME Panel 1, Panel 1
1A,0,0,0,1,NAME1,NAME2,NAME3,1,1,0,11111,0,0,0,0,0,0,0,NAME1,NA
ME2,NAME3,0
1B,1,0,0,1,NAME1,NAME2,NAME3,1,1,0,11111,0,0,22222,1,0,0,0,NAME
1,NAME2,NAME3,0
1C,1,0,0,1,,NAME2,,1,1,0,11111,0,0,22222,1,0,0,0,NAME1,NAME2,NAM
E3,0
.
.
//IFPANEL 10
///NAME Panel 10, Panel 10
.
4G,0,0,0,1,NAME1,NAME2,NAME3,1,1,0,11111,0,0,0,0,0,0,0,NAME1,NA
ME2,NAME3,0
4H,1,0,0,1,NAME1,NAME2,NAME3,1,1,0,11111,0,0,22222,1,0,0,0,NAME
1,NAME2,NAME3,0
<Details on Each Data Items>
Interface panel data: //IFPANEL <N1>
<N1>: File number of interface panel data
Interface panel group name: ///NAME <N2>,<N3>
<N2>: First language group name (12 one-byte characters)
<N3>: Second language group name (12 one-byte characters)
<Item Data>
<D1>,<D2>,<D3>,<D4>,<D5>,<D6>,<D7>,<D8>,<D9>,<D10>,<D11>,<D
12>,<D13>,<D14>,<D15>,<D16>,<D17>,<D18>,<D19>,<D20>,<D21>,<
D22>,<D23>
<D1>: Panel Arrangement
1A,1B,1C,1D,1E,1F,1G,1H,2A,⋅⋅⋅,4F,4G,4H Total: 32 positions (2
one-byte characters);
the lower-case letters cannot be used.
<D2>: Setup 0: Invalid 1: Valid
<D3>: Panel Type
0: Circle indication light (display only)
1: Circle indication light (push button)
5-1