Status Of Auxiliary Relay Signals At Power Supply On; Status Of I/F Panel Signals At Power Supply On - YASKAWA MOTOMAN FS100 Instructions Manual

Options for interface panel function, industrial robot arms
Hide thumbs Also See for MOTOMAN FS100:
Table of Contents

Advertisement

HW1480724
FS100

6.1.3 Status of Auxiliary Relay Signals at Power Supply ON

6.1.4 Status of I/F Panel Signals at Power Supply ON

6
Parameters
6.1
Clearing the Status of Signals
By setting parameters from S4C080 to S4C095, it allows to set the status
of auxiliary relay signals (#70010 to #79997) at the time of when turning
the power supply ON.
For the parameter settings, refer to the table below.
Parameters Auxiliary Relay
Signals
S4C080
#70010 to #70647
S4C081
#70650 to #71287
S4C082
#71290 to #71927
S4C083
#71930 to #72567
S4C084
#72570 to #73207
S4C085
#73210 to #73847
S4C086
#73850 to #74487
S4C087
#74490 to #75127
S4C088
#75130 to #75767
S4C089
#75770 to #76407
S4C090
#76410 to #77047
S4C091
#77050 to #77687
S4C092
#77690 to #78327
S4C093
#78330 to #78967
S4C094
#78970 to #79607
S4C095
#79610 to #79997
By setting parameters from S4C569 to S4C572, it allows to set the status
of I/F panel signals (#60010 to #60647) at the time of when turning the
power supply ON.
For the parameter settings, refer to the table below.
Parameters I/F Panel Signals
S4C569
#60010 to #60167
S4C570
#60170 to #60327
S4C571
#60330 to #60487
S4C572
#60490 to #60647
6-3
Set Values
Explanation
(Bit
When a bit specification is
specification)
set to "1", the status of
0: Clear,
auxiliary relay signals will be
1: Hold
held at the time of power
supply ON.
(Bit specification is to be set
by a series of 32 signals.)
Set Values
Explanation
(Bit
When a bit specification is
specification)
set to "1", the status of I/F
0: Hold,
panel signals will be cleared
1: Clear
at the time of power supply
ON.
(Bit specification is to be set
by a series of 8 signals.)