FloBoss S600 Instruction Manual
At the prompt ENTER NEW VALUE: key in the new value in integer, numeric, or scientific
5.
notation as appropriate (the current value and any entry limits associated with this parameter are
also shown).
Press Enter to confirm.
6.
The edit sequence is automatically exited on accepting or rejecting the value change if only one data item
is changeable on the data page.
If necessary, you can edit the new data as you key it in. Enter Change mode and use the ◄ key to delete
single figures or characters. If you wish to abort the change, press Clear.
Deleting or cancelling the change to the parameter should be done before pressing Enter. The Enter
command confirms that you wish the change to be written.
5.7.2 Changing Mode
To select a new calculation mode, the key sequence is similar to changing a value. The calculation modes
select a new source for a value; it will switch the value to the In-Use field.
Locate the parameter to be changed using one of the methods described under Section 5.6
If the mode is changeable, the mode is marked with an asterisk; if there is no asterisk, the mode cannot be
modified.
Steps 1 and 2 will be skipped if only one data item is changeable on the required data page.
Note:
Press Chng on the required data page.
1.
Select the required parameter using the ▲ or ▼ keys.
2.
Press Chng and the prompt ENTER CODE: displays.
3.
Key in your Security Code, and press Enter (the security code number does not display but each
4.
digit is indicated by a dot as you key it in).
At the prompt, select the required mode by using the appropriate numerical key (1 to 8).
5.
A second mode change window displays asking for confirmation. Press 1 to accept or 2 to reject
6.
the mode change.
The edit sequence is automatically exited on accepting or rejecting the mode change if only one data item
is changeable on the data page.
The Clear key enables you to cancel the mode change to the parameter, if necessary.