4.1.7 Raw Pulse Output
There is a single raw pulse output, typically used in prover applications to mimic the turbine signals and
send them to the prover mezzanine card. Refer to Figure 4-15. A 1 Kohm resistor is required if the pulse
rate on the prover bus exceeds 1 KHz, or if there are more than three streams, or if more than 20 m of cable
is required.
The RAWOUT pin connections are shown in Table 4-10.
Rev Sep/04
Table 4-9. PULSEOUT Pin Connections for SKT-B
Pin
30
PULSEOUT-CH1
31
PULSEOUT-CH2
32
PULSEOUT-CH3
33
PULSEOUT-CH4
35
RETURN CH1-4
34
PULSEOUT-CH5
12
RETURN CH5
Figure 4-15. Raw Pulse Output Schematic