Measurement Parameters - Dranetz Encore Serirs 6100 System Installation Manual

Table of Contents

Advertisement

Measurement Parameters

Measurement Parameters
Type: AC Voltage Modules
Voltage
Sampling rate: 512 samples per cycle
Connection:
Safety jack connectors (Model 61MVB)
Screw terminals (Model 61MVS - part number 117250-G1)
Voltage/Current external pod (Model 61MZP):
• 5536 voltage pod
Channels A, B, C, D Input Range: 0 - 600Vrms
Installation Category: CAT III, Pollution Degree 2
Input impedance: (Differential) 10 MΩ, minimum, Input to Ground on internal AC
input configurations
Impedance: (line to line) 20 MΩ
Crest factor: Maximum 2.0 at full scale
RMS accuracy:
±0.1% of Reading, ±0.05% Full Scale, over 7KHz bandwidth (1 second rms readings)
for low/medium frequency module
0.1% of Reading, over the nominal operating range of 50% to 100% Full Scale, as per
61000-4-30 Class A requirements, over the frequency range specified by 61000-4-30
Class A
Transient Duration: 32 usec standard at 60Hz; 39 usec at 50Hz
CMMR: -80 dB
Phase: Each voltage/current pair (i.e. Channel A voltage, Channel A current) are
sampled simultaneously to preserve phase relationship.
Frequency: Frequency ranges, user selectable
For standard model:
15 - 70 Hz for low frequency data, with 16 2/3, 20, 50 and 60 Hz defaults in Auto-
Config
B-4
Continued on next page

Advertisement

Table of Contents
loading

Table of Contents