Dranetz HDPQ-DN-MVSTR Quick Reference Manual

Dranetz HDPQ-DN-MVSTR Quick Reference Manual

Hdpq datanode with terminal block voltage and hypertronic current connectors

Advertisement

Quick Links

Quick Reference Guide
HDPQ DataNode with Terminal Block Voltage
and Hypertronic Current Connectors
(Dranetz Model HDPQ-DN-MVSTR)
Dranetz
1000 New Durham Road, Edison, New Jersey 08818
Telephone 1-800-372-6832 or 732-287-3680
Fax 732-248-1834
www.dranetz.com

Advertisement

Table of Contents
loading

Summary of Contents for Dranetz HDPQ-DN-MVSTR

  • Page 1 Quick Reference Guide HDPQ DataNode with Terminal Block Voltage and Hypertronic Current Connectors (Dranetz Model HDPQ-DN-MVSTR) Dranetz 1000 New Durham Road, Edison, New Jersey 08818 Telephone 1-800-372-6832 or 732-287-3680  Fax 732-248-1834 www.dranetz.com...
  • Page 2 No part of this book may be reproduced, stored in a retrieval system, or transcribed in any form or by any means—electronic, mechanical, photocopying, recording, or otherwise—without prior written permission from the publisher, Dranetz, Edison, NJ 08818-4019. Printed in the United States of America. P/N QR-HDPQ-DN-MVSTR Rev. C 04.04.19...
  • Page 3 ADVERTENCIA Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda este manual antes de conectar. Observe todas las instrucciones de instalación y operación durante el uso de este instrumento. La conexión de este instrumento a un sistema eléctrico se debe realizar en conformidad con el Código Eléctrico Nacional (ANSI/NFPA 70-2017) de los E.E.U.U., además de cualquier otra norma de seguridad correspondiente a su establecimiento.
  • Page 4 WARNUNG Der falsche Anschluß dieses Gerätes kann Tod, schwere Verletzungen oder Feuer verursachen. Bevor Sie dieses Instrument anschließen, müssen Sie die Anleitung lesen und verstanden haben. Bei der Verwendung dieses Instruments müssen alle Installation- und Betriebsanweisungen beachtet werden. Der Anschluß dieses Instruments muß in Übereinstimmung mit den nationalen Bestimmungen für Elektrizität (ANSI/NFPA 70-2017) der Vereinigten Staaten, sowie allen weiteren, in Ihrem Fall anwendbaren Sicherheitsbestimmungen, vorgenommen werden.
  • Page 5 Caution, refer to accompanying documents (this manual). Alternating current (AC) operation of the terminal or device. Direct current (DC) operation of the terminal or device. Safety Precautions The following safety precautions must be followed whenever any type of voltage or current connection is being made to the instrument. •...
  • Page 6: Table Of Contents

    TABLE OF CONTENTS Introduction…………………………………………….…… This Quick Reference Guide……….….………...………… Getting Started……………………………………………... Connecting to Power Source…..………………...………... Controls, Indicators and Connectors….………...………… Reset to Factory Defaults…..…..………………...………... Connecting to the HDPQ DataNode………………………. Connecting via Wired Ethernet Connection………………. Connecting via Wireless (WiFi) Connection……………… HDPQ IP Setup Program...……………………...…………. Making Measurement Connections……………………..
  • Page 7: Introduction

    The HDPQ-DN-MVSTR can monitor and record data on four voltage channels as well as four current channels simultaneously. Dranetz HDPQ-DN-MVSTR is designed to meet both the IEEE 1159 and IEC 61000-4-30 Edition 3 Class A standards for accuracy and measurement requirements. It can do PQ-optimized acquisition of power quality related disturbances and events.
  • Page 8: Getting Started

    GETTING STARTED Connecting to Power Source Power The power supply inputs are rated 90–250 VAC 50/60 Specifications Hz and 100-300 VDC. A screw terminal block is used to connect up to #12 AWG gauge wire for the power input connections. The positive and negative inputs are fused internally and the fuses are not user - replaceable.
  • Page 9 The AC/DC power input is found at the rear panel of the unit. The rear panel for DataNode Model HDPQ-DN-MVSTR is shown below. Power Source The rear panel marking provides information about the input power rating.
  • Page 10: Controls, Indicators And Connectors

    Controls, Indicators and Connectors Top View and Front View Top Panel The top panel shows the user replaceable Battery compartment. Internal Battery Sealed, rechargeable NiMH (Nickel Metal Hydride) cell The unit will always operate on the normal power source 50/60Hz, 90-250VAC or 100-300VDC. In the event of loss of power, the unit will seamlessly switch to the internal battery backup and will switch back to the normal power source when restored.
  • Page 11 Rear View This section describes the rear view panel of the HDPQ-DN-MVSTR. Digital Input (optional) – use to monitor on/off-type digital signals, such as breaker or switch position indicators. Ethernet Port – use to connect a wired Ethernet (RJ45) network.
  • Page 12: Reset To Factory Defaults

    Default User name: admin Default Password: Dranetz Wired Ethernet IP address will be fixed at 192.168.0.30. NOTE: All saved data and setups will be lost when you reset the instrument settings to factory defaults.
  • Page 13: Connecting To The Hdpq Datanode

    The next sections describe how to connect to the HDPQ DataNode via:  Wired Ethernet connection  Wireless (WiFi) connection (available as an option)  A proprietary Dranetz HDPQ IP Setup utility program if the IP Address is not known...
  • Page 14: Connecting Via Wired Ethernet Connection

    Enter the default User name: admin Enter the default Password: Dranetz User name and password are case sensitive, and must be entered as shown. When done entering the user name and password, click on the...
  • Page 15 Step Action The HDPQ DataNode Administrative Home Page will be displayed. Click the Commissioning Setup tab and select Ethernet Setup. Result: The following screen is displayed. On the Commissioning Setup - Ethernet Setup screen, enter the applicable setting changes and then click on the Submit Change button to connect to the instrument.
  • Page 16: Connecting Via Wireless (Wifi) Connection

    Connecting via Wireless (WiFi) Connection The steps below show how to connect to the HDPQ DataNode via a Wireless (WiFi) connection. NOTE: The steps below can be done only if the WiFi option is installed and a WiFi antenna is connected to the rear panel of the HDPQ instrument.
  • Page 17 Step Action Disconnect from any network to which the instrument is currently connected by pressing the DISCONNECT button to the right. The instrument will attempt to connect to any “remembered” WiFi networks. To clear the list of “remembered” networks, click on CLEAR.
  • Page 18: Hdpq Ip Setup Program

    HDPQ IP Setup Program A proprietary Dranetz setup utility program (HDPQIPSetup.exe) is designed to scan the local network to find and detect HDPQ DataNode units. This allows to you to discover HDPQ DataNodes on your network when you do not know the instrument’s IP address. The IP Setup program may be downloaded from the Dranetz website.
  • Page 19 Step Action Locate the MAC address of your HDPQ DataNode and click on that line in the HDPQ Device box. NOTE: A label on the HDPQ DataNode enclosure contains the MAC address. Click on the Get button to populate the left fields with your HDPQ Ethernet Settings.
  • Page 20 Once the HDPQ DataNode is set up, connect to the instrument to verify the settings. NOTE: You may have to change the Internet settings on your computer to connect.
  • Page 21: Making Measurement Connections

    MAKING MEASUREMENT CONNECTIONS WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand the warnings in the beginning of this guide before connecting this instrument. ADVERTENCIA Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio.
  • Page 22: Connecting The Voltage And Current Connectors

    Connecting the Voltage and Current Connectors The Dranetz Model HDPQ-DN-MVSTR offers the following circuit connection interfaces: Voltage Four (4) channel differential AC/DC Voltage Terminal Block Connectors labelled ±A, ±B, ±C and ±Neutral. Four (4) channel Hypertronic connectors labelled CH A, CH Current B, CH C, and CH D for connecting to current inputs.
  • Page 23 Use only fast blow type fuse which is rated 600V. Recommended fuse type is Littelfuse, part number KLKD.300 rated 600V AC/DC, 0.3A fast blow or Dranetz Fuse Voltage Adapter FVA- Do not replace fuse again if failure is repeated. WARNING Repeated failure indicates a defective condition that will not clear with replacement of the fuse.
  • Page 24: Connecting Current Probes

    Use only Dranetz current probes and adapter cables for proper operation. Do not exceed the marked maximum ratings. Be sure to observe the current specifications, as well as the arrow indicating the direction of current flow.
  • Page 25 Leitungen. Stromzangen dieses Typs sind nur fŸr Messungen an isolierten Leitern geeignet. Bitte verwenden Sie zur Messung an nicht isolierten Leitungen Stromzangen mit vollstŠndig isoliertem Kernmaterial --------------------------------------------------------------------------------- Dranetz Model HDPQ-DN-MVSTR can monitor the following power configurations:  Single Phase  Split Phase ...
  • Page 26: Single Phase

    When making connections to a single phase circuit, connect the voltage and current as shown below. The figure also includes monitoring the Neutral to Ground voltage. Neutral to ground measurements are important but optional. HDPQ-DN-MVSTR-101 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 27: Split Phase

    The Neutral is chosen as the reference for measurement purposes. The figure also includes monitoring the Neutral to Ground voltage. Neutral to ground measurements are important but optional. HDPQ-DN-MVSTR-102 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 28: Phase Four Wire Wye

    The neutral is connected to common and is the reference for all three voltage channels. The figure also includes monitoring the Neutral to Ground voltage. Neutral to ground measurements are important but optional. HDPQ-DN-MVSTR-103 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 29: Phase (Floating Or Grounded) Delta

    A monitoring phase A-B, channel B monitoring phase B-C, and channel C monitoring phase C-A. Current inputs are connected to line currents A, B, and C. HDPQ-DN-MVSTR-104 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 30: Phase 2-Watt Delta

    B as the reference channel . The Source voltage and current inputs (A and C) are measured by the instrument using voltage and current inputs (A and B). HDPQ-DN-MVSTR-105 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 31: 1/2 Element Without Voltage Channel B

    Channels A and C are connected to the voltage and the current sources. The neutral is connected to common and is the reference for the three channels. HDPQ-DN-MVSTR-106 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 32: 1/2 Element Without Voltage Channel C

    Channels A and B are connected to the voltage and the current sources. The neutral is connected to common and is the reference for the three channels. HDPQ-DN-MVSTR-107 CAUTION Connections must be performed in compliance with all safety requirements applicable to your installation.
  • Page 33: Accessories List

    ACCESSORIES LIST Standard Accessories The following table lists the standard accessories for Dranetz HDPQ-DN- MVSTR. Qty. Description Part Number Terminal Block, 2 Position 902388-LF Use for the input power connector. Terminal Block, 8 Position 902389-LF Use for voltage inputs. HDPQ DataNode with Terminal Block...
  • Page 34 Description Part Number For Three Phase (XLB Series) 118436-G1 DRANFLEX3003XLB, 30A/300A/3000A, 24” 118437-G1 DRANFLEX3003XLB, 30A/300A/3000A, 36” 118438-G1 DRANFLEX3003XLB, 30A/300A/3000A, 48” DRANFLEX6003XLB, 60A/600A/6000A, 24” 118442-G1 DRANFLEX6003XLB, 60A/600A/6000A, 36” 118443-G1 DRANFLEX6003XLB, 60A/600A/6000A, 48” 118444-G1 For Single Phase (MHB Series) 118430-G1 DRANFLEX300MHB, 3A/30A/300A, 6” 118431-G1 DRANFLEX300MHB, 3A/30A/300A, 8”...
  • Page 35: Digital Inputs Hdpq-Dn-Mdin (Optional)

    DIGITAL INPUTS HDPQ-DN-MDIN (optional) The factory-installed digital input option HDPQ-DN-MDIN is an eight channel, digital input module, providing users with the capability to monitor on/off-type digital signals, such as breaker or switch position indicators. A logical HI condition is when the voltage level goes above 3.0 volts and a logical LO condition is when the voltage level goes below 1.0 volts.
  • Page 36 Internal Supply Each channel 1 through 8 is referenced to the “COM” terminal. Individual channels can be connected between the “COM” to the “ – “ terminal of your monitoring source which serves as the reference. Each “+” terminal (1,2,3,4,5,6,7,8) of the instrument connects to the “+” terminal of your monitoring source.
  • Page 37: General Specifications

    GENERAL SPECIFICATIONS Dimensions Size: 11” Width x 3.5” Height x 8.5” Depth 28cm x 9cm x 22cm Weight: 4.5 pounds Power Consumption 25 watts max Environmental Operating: 0 to +55 °C (32 to 131 °F) Storage: -40 to +70 °C (-40 to 158 °F) Humidity: 5% to 95% non-condensing Altitude...