 Output Settings
Item
Judgment Output
Selection
Threshold
a
Displacement
Threshold
Judgment
b
Hysteresis RHH WHH
Judgment Output
OFF-delay
Measurement Value
Display on Panel
*1. The data section consists of 5 digits (zero suppress is omitted) indicated in
decimal.
Ramco National
800-280-6933 | nsales@ramcoi.com
Command
Data
+00000
+00001
ROD WOD
+00002
+00003
-9500000 to
RHA WHA
+9500000
-9500000 to
RHB WHB
+9500000
+0000000 to
+9500000
+00000
+00001
+00002
+00003
ROF WOF
+00004
+00005
+00006
+00007
+00000
RDS WDS
+00001
+00002
www.panasonicsensors.com
Description
Logic
Independent
2-state
3-state
-950.0000 to
+950.0000 [mm]
-950.0000 to
+950.0000 [mm]
+000.0000 to
+950.0000[mm]
OFF
2[ms]
4[ms]
10[ms]
20[ms]
40[ms]
100[ms]
Hold
FULL
SET 1
SET 2
Format
1
FORMAT
2
FORMAT
1
FORMAT