Reset - Panasonic HL-G1**-A-C5 User Manual

Hl-g1 series compact laser displacement sensor
Hide thumbs Also See for HL-G1**-A-C5:
Table of Contents

Advertisement

 Reset
The function resets the measurement value.
At the time of making a peak measurement, valley measurement, or peak-to-peak
measurement with external multi input (MI), the measurement value kept on hold
at the desired timing can be reset.
Input a specified pulse width as multi input.
The pulse width can be input into the high-function type through a communications
command.
refer to "2-4 Timing Chart".
For details,
All judgment outputs will be turned OFF when " Reset " is executed. This
function can be applied to judge each measurement object for peak, valley, or
peak-to-peak measurements.
• The data will be in an unfixed status when "Reset" is executed, and the analog
output outputs the alarm set in the "Analog Output at Alarm" (initial value holds
the analog output immediately before the alarm), and the judgment output
becomes a HI judgment.
• If Reset ON is executed by a communications command, the memory contents
will be cleared to zero after Reset is executed.
● Setting Procedure
1
Press the [UP]/[ENTER] keys together
while in Run mode.
Reset will be executed.