Command Formats; Format; General Purpose - Panasonic HL-G1**-A-C5 User Manual

Hl-g1 series compact laser displacement sensor
Hide thumbs Also See for HL-G1**-A-C5:
Table of Contents

Advertisement

4-2-2 Command Formats

The following section explains seven types of command formats transmitted
from an external host device to the HL-G1.
1

General Purpose

FORMAT

The following command formats are used to read or make general
measurement mode settings or operating conditions.
● Read Command
Read command formats are used to read operating conditions.
Request communication data
%
Destination no.
Normal response data
%
Sender no.
Ex
Reading the sampling cycle setting value for sensor 01 in the RS-422
handshake mode or the RS-485 multi-mode
Request communication data
% 0 1 # R S P
Normal response data
% 0 1 $ R S P +
Ramco National
CR
# R
BCC
Command
±
$ R
0 1 2 3 4
Command
CR
*
*
0 0 0 0 1
800-280-6933 | nsales@ramcoi.com
CR
BCC
Data block: 1 -character symbol +
5 -character integral part (no zero suppress)
CR
*
*
Sampling cycle:
500 [μs]
www.panasonicsensors.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl-g1**a-ra-c5Hl-g1**-s-jHl-g1**a-rs-j

Table of Contents