OUT3 settings are related to the operation of the output lines. An alarm is output through
the OUT3 output line unless a 3-state value has been set. The OUT3 indicator on the sensor
head and the OUT3 output readout function, however, will be turned OFF without being
interlocked with the alarm. Check the alarm state with the alarm indicator and alarm
readout function.
● Setting Procedure
1
Display the "Output Setting" screen while
the system is in setting mode.
2
Press the [ENTER] key. The "Judgment
Output Selection" screen will be
displayed.
3
Press the [ENTER] key. The present
output type will be displayed.
4
Press the [UP]/[DOWN] key to make
output type changes. (Example:
Changing the output type to
"Independent.")
5
Press the [ENTER] key to determine the
output type.