 Digital Output at Alarm
This function is used to set the digital output status at alarm operation.
This function makes settings related to digital output (on the digital display block
of the sensor head and measurement values over serial communication) in the
alarm state (where measurement is disabled owing to lack of light). The digital data
will be set to +99999 if the fixed value is selected. The measurement value
immediately before the alarm will be displayed if the system is set to hold.
Selecting the fixed value can detect the alarm issued status easily from the
measurement result. With this convenient function, the alarm status can be
confirmed as well when the measurement value is loaded by data buffering
function.
Setting
Hold
Fixed Value
*
indicates the default value.
• If the alarm state occurs after the fixed value is selected, judgment output
interlocked with digital output will be turned ON.
● Setting Procedure
1
Display the "Alarm Setting" screen while
in setting mode.
2
Press the [ENTER] key. The "Analog
output at alarm" screen will be displayed.
3
Press the [DOWN] key once. The "Digital
output at alarm" screen will be displayed.
4
Press the [ENTER] key. The present
Hold/Fix will be displayed.
5
Press the [UP]/[DOWN] key to select
Hold/Fix. (Example: Changing the
selection to the fixed value.)
6
Press the [ENTER] key to determine the
set value.
Ramco National
800-280-6933 | nsales@ramcoi.com
Function
Holds the digital output
immediately before the alarm.
Fixed-value output
Panel display
www.panasonicsensors.com