 Output Characteristics
● Diffuse reflection type
*1 In the figure above, analog output setting is used as the initial setting.
30-mm type
50-mm type
85-mm type
120-mm type HL-G112-A-C5
250-mm type HL-G125-A-C5
Ramco National
800-280-6933 | nsales@ramcoi.com
Measurement center distance (D)
0V
3.2 mA
High-function
Standard type
type
HL-G103-A-C5
HL-G103-S-J
HL-G105-A-C5
HL-G105-S-J
HL-G108-A-C5
HL-G108-S-J
HL-G112-S-J
HL-G125-S-J
Measurement (R)
Displacement
output
10 V
20 mA
5 V
12 mA
0 V
4 mA
Measurement center
distance (D)
30 mm
50 mm
85 mm
120 mm
250 mm
www.panasonicsensors.com
10.5 V
20.8 mA
Distance (mm)
Measurement
method (R)
±4 mm
±10 mm
±20 mm
±60 mm
±150 mm