 Analog Scaling
This function scales analog current output or analog voltage output to any
desired value.
Measurement values A and B on any two measurement point can be scaled with
currents a and b or voltages a and b on any two points. Analog output is turned ON
according to the scaling set for analog output selection.
Analog output
b
b'
a'
a
Measurement value A
Panel
Item
display
Meas A
Meas B
Current a
(*1)
Current b
(*1)
Voltage a
(*2)
Voltage b
(*2)
*1 Not displayed when "Voltage" is selected for "Analog Output Selection."
*2 Not displayed when "Current" is selected for "Analog Output Selection."
The following default measurement values A and B apply.
Type
30 mm
50 mm
85 mm
120 mm
250 mm
Ramco National
: Voltage/Current before change
: Voltage/Current after change
Measurement value B
Setting
range
-95000 to
+95000
-95000 to
+95000
Make
+4.000 to
measurement
20.000
value, current,
+4.000 to
and voltage
20.000
settings.
0 to +10.000
0 to +10.000
Diffuse reflection
Meas. Val A
Meas. Val B
-4 mm
+4 mm
-10 mm
+10 mm
-20 mm
+20 mm
-60 mm
+60 mm
-150 mm
+150 mm
800-280-6933 | nsales@ramcoi.com
Current voltage [V]/Current [mA]
Voltage [V]/Current [mA]
Measurement range
Function
Initial value
Negative
measurement range
Positive
measurement range
Specular reflection
Meas. Val A
Meas. Val B
-2 mm
-5 mm
-10 mm
-
-
www.panasonicsensors.com
+2 mm
+5 mm
+10 mm
-
-