Physical Specifications

Height
Width
Depth
Weight

Environmental Specifications

Temperature
Nonoperating
Operating
Humidity
Operating wet bulb
Nonoperating
Operating
Shock
Nonoperating
Operating
Altitude
Nonoperating
Operating
Acoustic noise
Electrostatic
discharge (ESD)
AC Input Power
115 VAC
230 VAC
M440LX Server System Product Guide
51.44 cm (20.25 inches)
43.56 cm (17.15 inches)
51.13 cm (20.13 inches)
29 kg (63 lbs.) minimum configuration
44 kg (97 lbs.) maximum configuration
–40° to 70 °C (–40° to 158 °F)
5° to 35 °C (41° to 95 °F); derated 0.5 °C for every
1000 ft (305 m)
Not to exceed 33 °C (91.4 °F) (with diskette drive or
hard disk drive)
95% relative humidity (noncondensing) at 55 °C (131 °F)
85% relative humidity (noncondensing) at 35 °C (95 °F)
20 g, 11 msec, 1/2 sine
2.0 g, 11 msec, 1/2 sine
To 50,000 ft (15,240 m)
To 10,000 ft (3,048 m)
Typically <45 dBA at 18° to 24 °C (65° to 75 °F) with five
internal hard disk drives (measured at 1 meter from the
system with the peripherals idle). The noise of the
variable-speed system fan will increase with
temperature and power load. Your selection of
peripherals may change the noise level.
Tested to 20 kilovolts (kV), no component damage.
(CD-ROM drive tested to 15 kV, manufacturer's
specification.)
Single power supply, fully loaded
100 to 120 VAC, 7.7 A, 50/60 Hz
200 to 240 VAC, 4.4 A, 50/60 Hz
41